Summer is coming, and every girl likes to wear light clothes, but she is troubled by the indecent body hair. There are long body hairs on the armpits, arms, and slender legs. Excessive hairs not only affect the external beauty of women, but also bring psychological harm to women to a greater extent. For this reason, some girls simply shave it off, while others use "depilatory cream" or drug depilatory methods, but the result is that more and more hairs are shed, and the hairs are darker and denser than before.
So how can hair removal be safer, healthier and more effective? Mu Ning International Beauty Equipment has introduced the most advanced OPT painless hair removal equipment to help you solve your troubles and make your beautiful summer without regrets.
What is opt?
OPT Perfect Pulsed Light is an intelligent, non-ablative skin reconstruction system that integrates epidermal cooling technology, IPL treatment technology, and RF radio frequency technology. The core technology OPT, the fourth-generation IPL, perfect pulse technology achieves uniform energy balance throughout the pulse, and professional sapphire cooling technology improves the effectiveness and safety of treatment. OPT Perfect Pulsed Light combines the above three technologies intelligently to provide targeted treatment plans for different skin types and skin problems of different patients. Under the premise of full protection of the epidermis (epidermal cooling technology), IPL technology can be used to uniquely lyse the epidermis; the intelligent combination (IPL+RF) allows the above two energies to be focused to the maximum extent on the spot-like pigments of the epidermis, the collagen tissue of the dermis, and the hair papilla of the hair follicles. RF technology provides an energy that evenly heats almost the entire skin layer, and at this time, the combined application of the selective photothermal principle of IPL can enhance the effects of skin rejuvenation, freckle removal, and hair removal, and easily achieve skin reconstruction and hair removal without obvious pain and side effects for patients.
OPT's excellent technical advantages avoid adverse postoperative reactions such as blisters, light spot marks, pigment reflux, etc. caused by photon, color light, and E-light. It is the safest, most reliable, and most cost-effective equipment for beauty salons, plastic surgery institutions, and hospitals.
What is IPL
Intense pulsed light (IPL) is a type of broad-spectrum visible light with a special wavelength and a gentle photothermal effect. Initially, it was mainly used in dermatology to treat skin telangiectasia and hemangiomas.
Intense pulsed light is a continuous, multi-wavelength, incoherent light with a wavelength range of 500 to 1200 nm. The intense pulsed light therapy device can select wavelengths through filters, so it has the effect of selectively removing pigment spots, blocking blood vessels, removing hair and wrinkles. When intense pulsed light is used to treat skin wrinkles, pigmentation, capillary dilation and other changes caused by photoaging, this technology is also called photorejuvenation.
Selective absorption of light + strong heat from light
Multi-wavelength, strong pulse, wide spectrum, color light will be decomposed into photons after quantitative decomposition. After irradiating the skin with the quantitative decomposed photons, it can reach all levels of the skin, decompose abnormal pigment cells; destroy hair follicles; close abnormal blood vessels; stimulate collagen proliferation, and rearrange elastic fibers at the same time, so as to achieve the effects of freckle removal, ER nano-light hair removal, removal of red blood, and whitening and tender skin. Freckle removal relies on metabolism to remove abnormal pigments from the body.
effect:
Wrinkle removal - effectively eliminate and relieve wrinkles of varying degrees around the eyes and forehead;
Skin rejuvenation - shrink pores, improve skin texture, and increase skin elasticity;
Skin tightening - improve skin elasticity and increase skin smoothness;
Whitening - remove freckles, age spots, acne, etc., decompose melanin and make the skin white.
Advantages of OPT three-in-one hair removal device
Hair Removal Advantages 1
Safe and comfortable: Traditional laser hair removal is very painful during treatment because the laser has high brightness and high energy density. The irradiation treatment is similar to a concentrated sun exposure of the skin. In order to prevent epidermal damage, freezing point hair removal has a special cooling device, so the freezing point hair removal process is almost painless!
Hair Removal Advantages 2
Optimal pulse, removes hair without damaging the skin: The pulse required for freezing point hair removal is related to the thickness of the hair. The thicker the hair, the longer the effect required. The laser pulse for hair removal ranges from 5 milliseconds to 100 milliseconds. While achieving the ideal leg hair removal effect, it effectively protects the skin from heat damage.
Hair Removal Advantages 3
Directly hit the hair root, never regenerate: This hair removal method can penetrate the epidermis, enter the dermis, completely shrink the hair follicles and hair shafts, and produce permanent hair removal. The other parts of the hair follicles do not contain melanin particles, so they do not absorb this laser, and will not cause harm. It is safer and more thorough.
Hair Removal Advantages 4
The effect is immediate: the freezing point laser wavelength can penetrate into the deep layer of the dermis and subcutaneous fat tissue, acting on hair follicles at different locations and depths, quickly and thoroughly removing hair at any location and depth on the human body.
Hair Removal Advantages 5
No pigmentation: Traditional laser hair removal causes skin pigmentation and inflammation after hair removal, while the nearly perfect freezing point laser hair removal has a deeper penetration depth and the epidermis absorbs very little energy, so there is no pigmentation.
Hair Removal Advantages 6
The skin is smooth and delicate: Freezing point hair removal has the effect of skin rejuvenation. With the proliferation of subcutaneous collagen, the pores are tightened after hair removal, and the skin of the body becomes smooth and shiny after hair removal.
working principle
The hair follicles contain a large number of melanocytes that absorb light of a specific wavelength. Therefore, the multifunctional OPT beauty instrument uses the principle of selective photothermolysis of a patented intense pulse light source to irradiate the hair follicles with light that is particularly sensitive to the melanocytes of the hair follicles but does not damage the normal epidermis, causing the hair follicles to generate heat and selectively destroy the hair follicles. At the same time, the emitted heat is transmitted to the deep part of the hair follicles through the cross section of the hair shaft, causing the temperature of the hair follicles to rise rapidly, causing irreversible damage to the hair follicle structure, and the damaged hair and hair follicles are removed through a natural physiological process, thereby achieving the effect of permanent hair removal while avoiding damage to surrounding tissues.
Difference from traditional hair removal
OPT freezing point hair removal instrument is different from traditional hair removal, which relies on external coupling agent or cold gel to achieve the effect of local rapid cooling. However, freezing point hair removal does not require this at all, which greatly reduces the operating costs of beauty salons in the later stage. The original sapphire probe directly acts on the epidermis, which can make the subcutaneous skin temperature reach -4℃ instantly, achieving true freezing point painless hair removal.
Compared with the defects of other traditional hair removal methods, the freezing point hair removal effect of OPT hair removal instrument is more convenient, more comfortable, and has fewer side effects, which can also be understood as no side effects. It can remove hair of different thicknesses at one time, whether it is fine lip hair, facial hair, or coarse hand hair, leg hair, chest hair, or even the bikini line in the private parts, it can help you easily remove it. The hair removal process of OPT instrument is comfortable, and you can hardly feel the pain. There is only a slight tingling sensation, which is almost negligible. These advantages are unmatched by traditional methods such as electroacupuncture or wax hair removal.
Instrument accessories
HR Probe Operation Items
Freezing point hair removal (hair removal):
Perfect pulsed light with a wavelength of 530nm-1200nm is used to act on human skin hair at different depths. The filtered pulsed light is easily absorbed by the melanin in the hair and hair follicles and converted into heat energy. The heat energy rapidly heats up the hair shaft and hair follicles. When the temperature reaches above 60°C, it causes hair splitting, hair follicle degeneration, hair papilla destruction, hair growth cell death, and ultimately the original hair falls off. New hair growth is delayed, thinned, lightened, and even stops growing. However, it does not affect the sweat glands.
Operation time: 20 minutes 30 days/time
For small areas of hair removal (such as liquid hair, lip hair, hairline), apply gel, put the probe close to the skin, press the light button once, move the light beam to the next place, and press it again, just like stamping.
1. Adjust the energy until the patient feels a tingling sensation and the skin turns slightly red for the best effect. Apply about 5 to 7 times.
2. Do not stay on the same spot of the skin and hit it continuously.
3. The probe must be close to the skin, otherwise the virtual contact may be too hot.
For large areas of hair removal (such as arm hair, chest hair, and calf hair), apply gel, keep the probe close to the skin, keep pressing the light button on the handle, and slide it on the skin in sequence. You can use the cross method, horizontally, then vertically.
After the hair removal operation, the hair follicles will not change much from before the operation. You will see the burrs are still there, but don't worry, the hair will become shorter and thinner after a month. Repeated treatment will not cause hair to grow again.
SR probe operation items
1. Remove freckles
l Perfect pulse light waves act on the skin. Since the content of pigment clusters in the diseased tissue is much higher than that in normal skin tissue, after absorbing the pulse light, the light energy absorbed by the diseased tissue is much higher than that of normal skin, and the pigment breaks and decomposes. Since normal skin tissue absorbs less light and heat, it does not damage the normal skin tissue. The melanin that absorbs light will form scabs on the epidermis in the later stage.
Note: Only epidermal spots such as freckles, sun spots, and age spots can be treated
Deep spots: Chloasma, Nevus of Ota, and zygomatic freckles cannot be removed because the light emitted by OPT is scattered. Flake spots will absorb light over a large area. It is recommended not to do so, or use point-to-point laser to remove them, such as picosecond laser.
Operation time: 30 minutes 45-60/time 3 times/treatment
(1) Remove makeup for 2 minutes (mild cleansing milk)
(2) Cleanse for 2 minutes (moisturizing cleanser)
(3) You must analyze the spots first. You can only analyze the epidermal spots, such as freckles and sun spots. (Skin detector) 5 minutes
(4) Apply gel and place the probe close to the skin with spots. Press the light button once and move the light beam to the next spot. Press it again, like stamping a stamp. (Gel) for 10 minutes
Note: Adjust the energy until the customer feels a noticeable stinging and hot sensation, and the skin becomes slightly red and the spots are darker than before the treatment. This is the best effect and you can stop the treatment now. Only operate on the areas with spots.
(5) After the operation is completed, wipe off the gel, apply a mask, and apply repair water and repair cream (regeneration repair water and repair cream) for 2 minutes.
2. Photorejuvenation (for dull, oily, and enlarged pore skin)
l Perfect pulse light combined with RF radio frequency can reach a depth of 15mm to stimulate the fibrotic tissue of the dermis. The energy provided by RF technology almost evenly heats the entire skin layer, promotes collagen proliferation, achieves skin rejuvenation and whitening, shrinks pores, and improves facial sagging;
Operation time: 45 minutes 3 times/course 30 days/time
(1) Remove makeup for 2 minutes (mild cleansing milk)
(2) Cleanse for 2 minutes (moisturizing cleanser)
(3) Apply gel, press the light button once, move the light beam to the next place, and press it again, like stamping, on the whole face, 15 minutes (gel)
Note: The light spot cannot be applied to eyebrows, eyes, or lips. It can only be applied to the skin that can be manipulated.
(4) Adjust the energy until the patient feels a tingling sensation for the best effect. Repeat the procedure on the entire face about 5 times.
(5) After the operation, you can apply a moisturizing mask for 20 minutes (EGF mask)
(6) Apply 8 water, regenerating essence, moisturizing lotion, regenerating face cream, revitalizing eye cream, and sunscreen for 2 minutes
You can then put on makeup normally after the treatment
3. Assist in removing acne
l Use the specified wavelength light energy to reduce the active propionibacterium of the sebaceous glands while eliminating pigmentation, stimulating deep collagen proliferation, and thus achieving a good effect in treating acne.
Preoperative examination
l Ask the customer if they are allergic to light. A small number of people will experience redness, swelling and itching when exposed to the sun. This phenomenon should not be treated with optical instruments;
The same part can only be treated with photon once a month. Repeated treatments within a month are not allowed;
People with scar-prone constitutions should not undergo freckle removal. After freckle removal with optical instruments, tiny scabs will form on the skin.
The treatment light should be kept away from reflective mirrors and eyes, and jewelry, watches and other accessories should not be worn during the treatment process;
Open wounds, cystic acne skin, skin with dense red blood streaks, moles, and skin with pigmented flakes on the face are prone to injury and should not be operated on or avoided;
Do not do it if you have severe three highs (high blood lipids, high blood pressure, and high blood sugar) or three periods (menstrual period, pregnancy period, and lactation period);
People with serious diseases, such as heart disease, pacemakers, or diabetes should not do this;
It is not suitable for people with allergic skin, vitiligo, lupus erythematosus and other skin diseases;
Avoid facial plastic surgery;
Treatment is not recommended for those who have used other methods of hair removal (such as waxing) within 6 weeks;
Don’t do it if you have had sunburn in the past 10 days or so
Treatment is not recommended for those who have used other methods of hair removal (such as waxing) within 6 weeks;
Don’t do it if you have been exposed to the sun in the past 10 days or so.
Adjustment parameters
The core of parameter adjustment: the adjustment of parameters is a gradual process from shallow to deep according to the customer's feeling, so as to maximize the safety effect; the adjustment of energy is mainly for pigmentation problems, and the adjustment of energy and RF is mainly for skin rejuvenation problems. If the customer cannot accept too high energy, it will cause burns, so remember!
Professional Mode
First pulse: Pulse width: refers to the duration of each sub-pulse of the millisecond (ms) pulse light (heat penetration time), referred to as pulse width. The longer the pulse width, the deeper the heat penetrates, but the less heat is distributed in a single layer of skin. The first value is the first pulse, which refers to the width of the first pulse in the pulse train, and the next two values are sub-pulses.
Pulse delay: also known as pulse interval, refers to the time interval between sub-pulses, measured in milliseconds (ms); the longer the pulse delay, the more thorough the skin cooling, but the temperature of the lesion will also decrease.
Pulse number: refers to the number of sub-pulses contained in the pulse train
Treatment
project
Treatment/treatment
Intervals
Hair Removal (Fine Hair)
5-8 times
1-2 months/once
Hair Removal (Coarse Hair)
4-6 times
1-2 months/once
Photorejuvenation
3 times
1 piece/once
Spot removal
3 times
45-60 days/once
Operating procedures
1. Preheat the machine for 3 minutes before operating the probe. The machine needs to run the water circulation cooling system to cool the treatment head (frost or condensation).
2. Clean the probe, first disinfect it with alcohol, then wipe off the alcohol with saline
3. Shaving (don’t shave too cleanly, a little bit of burrs will absorb light better)
4. Ask the customer to wear protective glasses and the operator to wear special sunshade glasses
5. Apply gel, about the thickness of a coin, to relieve heat, guide light and lubricate
Postoperative Care
1. After the treatment, the customer should stay for 10 minutes for observation. If there is obvious burning sensation, ice packs can be used to cool the customer.
2. Remind customers to stay indoors as much as possible within one month and avoid sun exposure (because after using optical instruments, it is equivalent to being exposed to very strong light, and the sun is also light. Absorbing light again will harm the skin). When going out, hold an umbrella and apply sunscreen with SPF30 or above.
3. Do not take a sauna or hot spring bath for one week after treatment, and do not allow the operated parts to come into contact with overheated water. Pay attention to ventilation and heat dissipation.
You can put on makeup one or two days after the scabs fall off. Do not apply any makeup on the treated area during the scab period. Stop using skin care products and other freckle removal products within three months of the freckle removal project.
4. Avoid spicy food, seafood, pigmented food, photosensitive food and other irritating foods when removing spots
5. Do not touch water for 3-4 days to remove spots, and pay attention to cleaning (use saline or distilled water to wipe and keep the treated area clean and fresh)
6. If you feel itchy during the scab formation period after one week of freckle removal, do not scratch it with your hands. Let the scab fall off naturally.
7. Do not take a sauna or do strenuous exercise during the one-week scab formation period.
8. Do hydrating care (such as applying a facial mask) ten days after removing freckles
Warning Notes
1. If the machine works for more than 2 hours, shut it down and let the instrument rest for 20 minutes.
2. The probe handle can be used 100,000 times. When the number of times is used up, you can buy a gun head from our company.
3. The strong light hazard warning refers to the strong light emitted from the front of the treatment light head that can shine into the eyes, which can easily cause danger. The operator is required to wear protective glasses during operation and protect the person being operated to prevent the strong light from directly shining into the human eyes.
4. The water tank of the instrument must be filled with water before use.
5. When you need to change different function options, the machine must be in standby mode (the standby button is red). Function options cannot be changed in the ready state.
【Statement】: Low temperature areas below 0℃
6. If the instrument is not used for a long time, or needs to be used in a different location, the water inside (handle and main unit) must be drained.
7. Try not to place the instrument in an environment below 0℃ for more than 3 hours. Studies have found that water below 0℃ will experience a "surge" phenomenon when moving. Specifically, liquid water below 0℃ will freeze rapidly during movement. After liquid water turns into solid ice, its volume increases rapidly, causing certain damage to water pipes, internal water channels of cooling fans, laser water channels and other components.